Olivetti D-COPIA 2001 User Manual Page 63

  • Download
  • Add to my manuals
  • Print
  • Page
    / 82
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 62
59
TROUBLESHOOTING
6
B. Misfeed in the fusing area
1
Push gently on both ends of the front
cover and open it.
2
Turn the roller rotating knob in the
direction of the arrow.
3
Carefully remove the misfed paper.
Lower the fusing unit release levers to
allow easier removal.
Be careful not to tear the
misfed paper during
removal.
4
Lift the fusing unit release levers, to
return them to their operating
positions.
5
Close the front cover and side cover.
The misfeed indicator
( ) will go out.
The fusing unit is hot. Do not touch
the fusing unit when removing misfed
paper. Doing so may cause a burn or
injury.
Do not touch the photoconductive drum
(green portion) when removing the misfed
paper. Doing so may damage the drum and
cause smudges on copies.
Be careful about unfixed toner on the
misfed paper not to soil your hands or
clothes.
Roller rotating knob
Fusing unit
release lever
Warning
Caution
When closing the front cover, gently hold
both ends.
When closing the side cover, press on the
handle.
If the misfeed indicator ( ) does not stop
blinking, check for torn pieces of paper in
the machine.
Note
Page view 62
1 2 ... 58 59 60 61 62 63 64 65 66 67 68 ... 81 82

Comments to this Manuals

No comments